Click on a Model Number to view details. Click a column heading to sort.
All thermal tests performed with 1" insulated glass consisting of 1/4" TIAC40 (Low-E
#2) annealed/ Argon with TGI Spacer /1/4" Clear annealed. All thermal tests performed
using in house software recognized by NFRC.
| Model Number | Description | Frame Depth | Typical Wall Thickness | AAMA Rating | Struct. (PSF) | Air (CMF/SF) | Water (PSF) | U-Value | SHGC | STC | Blast | impact | Dual Glazed w/Blinds | *Grid Opt. | Sash Wgt | Test Size |
|---|
|
G101
|
Project-Out Bottom Awning
| 2.500 | 0.0800 |
AW 100
| 150 | <0.1 | 15.0000 | 0.402 |
0.284
|
27-45
| Avl | Avl | No |
A-I-T
| 120 |
60 X 36
|
|
G105
|
Fixed/Project Out Bottom-Awning
| 2.500 | 0.0800 |
AW 80
| 120 | <0.1 | 15.0000 | 0.353 |
0.322
|
27-45
| Avl | Avl | No |
A-I-T
| 120 |
60 X 99
|
|
G111
|
Project In Top-Hopper
| 2.500 | 0.0800 |
AW 100
| 150 | <0.1 | 15.0000 | 0.402 |
0.284
|
27-43
| Avl | Avl | No |
A-I-T
| 120 |
60 X 36
|
|
G121
|
Fixed/Project In Top-Hopper
| 2.500 | 0.0800 |
AW 80
| 120 | <0.1 | 15.0000 | 0.353 |
0.322
|
27-43
| Avl | Avl | No |
A-I-T
| 120 |
60 X 99
|
|
G141
|
Fixed
| 2.500 | 0.0800 |
AW 70
| 105 | <0.1 | 15.0000 | 0.313 |
0.350
|
27-43
| Avl | Avl | No |
A-I-T
| 300 |
60 X 99
|
|
G142
|
Fixed/Fixed
| 2.500 | 0.0800 |
AW 80
| 120 | <0.1 | 15.0000 | 0.332 |
0.341
|
27-45
| Avl | Avl | No |
A-I-T
| 300 |
60 x 99
|
|
G151
|
Casement Outswing Left
| 2.500 | 0.0800 |
AW 65
| 97.5 | <0.1 | 15.0000 | 0.372 |
0.305
|
27-46
| Avl | Avl | No |
A-I-T
| 120 |
48 X 71
|
|
G155
|
Casement Outswing Right
| 2.500 | 0.0800 |
AW 65
| 97.5 | <0.1 | 15.0000 | 0.372 |
0.305
|
27-46
| Avl | Avl | No |
A-I-T
| 120 |
48 X 71
|
|
G161
|
Casement Inswing Left
| 2.500 | 0.0800 |
AW 65
| 97.5 | <0.1 | 15.0000 | 0.372 |
0.305
|
27-46
| Avl | Avl | No |
A-I-T
| 120 |
48 X 71
|
|
G165
|
Casement Inswing Right
| 2.500 | 0.0800 |
AW 65
| 97.5 | <0.1 | 15.0000 | 0.372 |
0.305
|
27-46
| Avl | Avl | No |
A-I-T
| 120 |
48 X 71
|
|
G1T1
|
Casement Inswing Left Tilt/Turn
| 2.500 | 0.0800 |
AW 60/65
| 90/97.5 | <0.1 | 15.0000 | 0.345 |
0.323
|
27-46
| Avl | Avl | No |
A-I-T
| 120 |
60 X 99
|
|
G1T5
|
Casement Inswing Right Tilt/Turn
| 2.500 | 0.0800 |
AW 60/65
| 90/97.5 | <0.1 | 15.0000 | 0.345 |
0.323
|
27-46
| Avl | Avl | No |
A-I-T
| 120 |
60 X 99
|
|
G201
|
Project-Out Bottom Awning
| 3.250 | 0.0800 |
AW 100
| 150 | <0.1 | 15.0000 | 0.379 |
0.283
|
27-45
| Avl | Avl | No |
A-I-T
| 120 |
60 X 36
|
|
G205
|
Fixed/Project Out Bottom Awning
| 3.250 | 0.0800 |
AW 80
| 120 | <0.1 | 15.0000 | 0.341 |
0.321
|
27-45
| Avl | Avl | No |
A-I-T
| 120 |
60 X 99
|
|
G211
|
Project In Top-Hopper
| 3.250 | 0.0800 |
AW 100
| 150 | <0.1 | 15.0000 | 0.379 |
0.283
|
27-43
| Avl | Avl | No |
A-I-T
| 120 |
60 X 36
|
|
G221
|
Fixed/ Project In Top-Hopper
| 3.250 | 0.0800 |
AW 80
| 120 | <0.1 | 15.0000 | 0.341 |
0.321
|
27-43
| Avl | Avl | No |
A-I-T
| 120 |
60 X 99
|
|
G241
|
Fixed
| 3.250 | 0.0800 |
AW 70
| 105 | <0.1 | 15.0000 | 0.308 |
0.350
|
27-43
| Avl | Avl | No |
A-I-T
| 300 |
60 X 99
|
|
G242
|
Fixed/Fixed
| 3.250 | 0.0800 |
AW 80
| 120 | <0.1 | 15.0000 | 0.326 |
0.340
|
27-45
| Avl | Avl | No |
A-I-T
| 300 |
60 X 99
|
|
G251
|
Casement Outswing Left
| 3.250 | 0.0800 |
AW 65
| 97.5 | <0.1 | 15.0000 | 0.362 |
0.303
|
27-46
| Yes | Avl | No |
A-I-T
| 120 |
48 X 71
|
|
G255
|
Casement Outswing Right
| 3.250 | 0.0800 |
AW 65
| 97.5 | <0.1 | 15.0000 | 0.362 |
0.303
|
27-46
| Yes | Avl | No |
A-I-T
| 120 |
48 X 71
|
|
*Grid Options: A=Applied, I=Internal, T=True Muntin
**Avl = Available