Model NumberDescriptionFrame DepthTypical Wall ThicknessAAMA RatingStruct. (PSF)Air (CMF/SF)Water (PSF)U-ValueSHGCSTCBlastimpactDual Glazed w/Blinds*Grid Opt.Sash WgtTest Size
1201
Project Out Bottom-Awning
3.7500.1250
AW 90
135<0.112.00000.491
0.284
38-47
No No Yes
A-I-T
120
60 X 36
1205
Project Out Bottom-Awning
3.7500.1250
AW 95
142.5<0.112.00000.422
0.321
38-47
YesNo Yes
A-I-T
120
60 X 99
1211
Project In Top-Hopper
3.7500.1250
AW 90
135<0.112.00000.479
0.289
38-47
No No Yes
A-I-T
120
60 X 36
1221
Project In Top-Hopper
3.7500.1250
AW 95
142.5<0.112.00000.417
0.324
38-47
No No Yes
A-I-T
120
60 X 99
1241
Fixed
3.7500.1250
AW 85
127.5<0.112.00000.367
0.345
35-48
YesYes-60 X 60Yes
A-I-T
300
60 x 99
1242
Fixed/Fixed
3.7500.1250
AW 100
150<0.112.00000.397
0.337
35-48
YesYes-64 X 72Yes
A-I-T
300
60 X 99
1245
Fixed-Fixed
3.7500.1250
AW100
150<0.112.00000.397
0.337
35-48
YesYes-72 X 64Yes
A-I-T
300
60 X 99
1251
Casement Outswing Left
3.7500.1250
AW 90
135<0.112.00000.486
0.283
43-46
YesNo Yes
A-I-T
120
36 X 60
1252
Casement Outswing Left-Casement Outswing Right
3.7500.1250
AW 90
135<0.112.00000.473
0.291
43-46
No Yes-72 X 64No
A-I-T
120
72 X 60
1253
Casement Outswing Left-Fixed
3.7500.1250
AW 90
135<0.112.00000.422
0.321
43-46
No No Yes
A-I-T
120
99 X 60
1254
Fixed-Casement Outswing Right
3.7500.1250
AW 90
135<0.112.00000.422
0.321
43-46
No No Yes
A-I-T
120
99 X 60
1255
Casement Outswing Right
3.7500.1250
AW 90
135<0.112.00000.486
0.283
43-46
YesNo Yes
A-I-T
120
36 X 60
1261
Casement Inswing Left
3.7500.1250
AW 90
135<0.112.00000.479
0.289
43-46
No No Yes
A-I-T
120
36 X 60
1265
Casement Inswing Right
3.7500.1250
AW 90
135<0.112.00000.479
0.289
43-46
No No Yes
A-I-T
120
36 X 60
1294
(Fixed/Fixed)/Fixed
3.7500.1250
AW 60
90<0.112.0000NT
NT
35-48
No Yes-72 X 84Yes
A-I-T
300
72 X 84
1801
Project Out Bottom-Awning
2.0000.1250
AW 100
150<0.112.00000.430
0.300
36-41
YesNo Yes
A-I-T
120
60 X 36
1805
Fixed/Project Out Bottom-Awning
2.0000.1250
AW 75
112.5<0.112.00000.364
0.333
36-41
YesYes-48 X 72Yes
A-I-T
120
60 X 99
1811
Project In Top-Hopper
2.0000.1250
AW 100
150<0.112.00000.426
0.300
36-41
No No Yes
A-I-T
120
60 X 36
1821
Fixed/Project In Top-Hopper
2.0000.1250
AW 75
112.5<0.112.00000.362
0.333
36-41
No No Yes
A-I-T
120
60 X 99
1841
Fixed
2.0000.1250
AW 75
112.5<0.115.00000.318
0.355
35-41
YesYes-48 X 72Yes
A-I-T
300
60 X 99