Click on a Model Number to view details. Click a column heading to sort.
All thermal tests performed with 1" insulated glass consisting of 1/4" TIAC40 (Low-E
#2) annealed/ Argon with TGI Spacer /1/4" Clear annealed. All thermal tests performed
using in house software recognized by NFRC.
| Model Number | Description | Frame Depth | Typical Wall Thickness | AAMA Rating | Struct. (PSF) | Air (CMF/SF) | Water (PSF) Low | Water (PSF) High | U-Value | SHGC | STC | Blast | impact | Dual Glazed w/Blinds | *Grid Opt. | Sash Wgt | Test Size |
|
1251
|
Casement Outswing Left
| 3.750 | 0.1250 |
AW 90
| 135 | <0.1 | 12.0000 | | 0.486 |
0.283
|
43-46
| Yes | No | Yes |
A-I-T
| 120 |
36 X 60
|
|
1252
|
Casement Outswing Left-Casement Outswing Right
| 3.750 | 0.1250 |
AW 90
| 135 | <0.1 | 12.0000 | | 0.473 |
0.291
|
43-46
| No | Yes-72 X 60 | No |
A-I-T
| 120 |
72 X 60
|
|
1253
|
Casement Outswing Left-Fixed
| 3.750 | 0.1250 |
AW 90
| 135 | <0.1 | 12.0000 | | 0.422 |
0.321
|
43-46
| No | No | Yes |
A-I-T
| 120 |
99 X 60
|
|
1254
|
Fixed-Casement Outswing Right
| 3.750 | 0.1250 |
AW 90
| 135 | <0.1 | 12.0000 | | 0.422 |
0.321
|
43-46
| No | No | Yes |
A-I-T
| 120 |
99 X 60
|
|
1255
|
Casement Outswing Right
| 3.750 | 0.1250 |
AW 90
| 135 | <0.1 | 12.0000 | | 0.486 |
0.283
|
43-46
| Yes | No | Yes |
A-I-T
| 120 |
36 X 60
|
|
1261
|
Casement Inswing Left
| 3.750 | 0.1250 |
AW 90
| 135 | <0.1 | 12.0000 | | 0.479 |
0.289
|
43-46
| No | No | Yes |
A-I-T
| 120 |
36 X 60
|
|
1265
|
Casement Inswing Right
| 3.750 | 0.1250 |
AW 90
| 135 | <0.1 | 12.0000 | | 0.479 |
0.289
|
43-46
| No | No | Yes |
A-I-T
| 120 |
36 X 60
|
|
1851
|
Casement Outswing Left
| 2.000 | 0.1250 |
AW 100
| 150 | <0.1 | 12.0000 | 0.0000 | 0.430 |
0.300
|
36-41
| Yes | Yes-40 X 66 | Yes |
A-I-T
| 120 |
36 X 60
|
|
1852
|
Casement Outswing Left- Casement Outswing Right
| 2.000 | 0.1250 |
AW 75
| 112.5 | <0.1 | 12.0000 | 0.0000 | 0.419 |
0.306
|
36-41
| No | No | Yes |
A-I-T
| 120 |
72 X 60
|
|
1853
|
Casement Outswing Left- Fixed
| 2.000 | 0.1250 |
AW 75
| 112.5 | <0.1 | 12.0000 | 0.0000 | 0.364 |
0.333
|
36-41
| No | No | Yes |
A-I-T
| 120 |
99 X 60
|
|
1854
|
Fixed- Casement Outswing Right
| 2.000 | 0.1250 |
AW 75
| 112.5 | <0.1 | 12.0000 | 0.0000 | 0.364 |
0.333
|
36-41
| No | No | Yes |
A-I-T
| 120 |
99 X 60
|
|
1855
|
Casement Outswing Right
| 2.000 | 0.1250 |
AW 100
| 150 | <0.1 | 12.0000 | 0.0000 | 0.430 |
0.300
|
36-41
| Yes | Yes-40 X 66 | Yes |
A-I-T
| 120 |
36 X 60
|
|
1861
|
Casement Inswing Left
| 2.000 | 0.1250 |
AW 100
| 150 | <0.1 | 12.0000 | 0.0000 | 0.424 |
0.300
|
36-41
| No | No | Yes |
A-I-T
| 120 |
36 X 60
|
|
1862
|
Casement Inswing Left- Casement Inswing Right
| 2.000 | 0.1250 |
AW 100
| 150 | <0.1 | 12.0000 | 0.0000 | 0.415 |
0.304
|
36-41
| No | No | Yes |
A-I-T
| 120 |
72 X 60
|
|
1863
|
Casement Inswing Left- Fixed
| 2.000 | 0.1250 |
AW 75
| 112.5 | <0.1 | 12.0000 | 0.0000 | 0.362 |
0.333
|
36-41
| No | No | Yes |
A-I-T
| 120 |
99 X 60
|
|
1865
|
Casement Inswing Right
| 2.000 | 0.1250 |
AW 100
| 150 | <0.1 | 12.0000 | 0.0000 | 0.424 |
0.300
|
36-41
| No | No | Yes |
A-I-T
| 120 |
36 X 60
|
|
1951
|
Casement Outswing Left
| 4.500 | 0.1250 |
AW 100
| 150 | <0.1 | 12.0000 | 0.0000 | 0.480 |
0.297
|
36-41
| Yes | Yes-40 X 66 | Yes |
A-I-T
| 120 |
36 X 60
|
|
1955
|
Casement Outswing Right
| 4.500 | 0.1250 |
AW 100
| 150 | <0.1 | 12.0000 | 0.0000 | 0.480 |
0.297
|
36-41
| Yes | Yes-40 X 66 | Yes |
A-I-T
| 120 |
36 X 60
|
|
1961
|
Casement Inswing Left
| 4.500 | 0.1250 |
AW 100
| 150 | <0.1 | 12.0000 | 0.0000 | 0.480 |
0.291
|
36-41
| No | No | Yes |
A-I-T
| 120 |
36 X 60
|
|
1965
|
Casement Inswing Right
| 4.500 | 0.1250 |
AW 100
| 150 | <0.1 | 12.0000 | 0.0000 | 0.480 |
0.291
|
36-41
| No | No | Yes |
A-I-T
| 120 |
36 X 60
|
|
*Grid Options: A=Applied, I=Internal, T=True Muntin
**Avl = Available