You are hereProducts > Product List
  |  Login
 Casement
Click on a Model Number to view details. Click a column heading to sort.
All thermal tests performed with 1" insulated glass consisting of 1/4" TIAC40 (Low-E #2) annealed/ Argon with TGI Spacer /1/4" Clear annealed. All thermal tests performed using in house software recognized by NFRC.
Model NumberDescriptionFrame DepthTypical Wall ThicknessAAMA RatingStruct. (PSF)Air (CMF/SF)Water (PSF) LowWater (PSF) HighU-ValueSHGCSTCBlastimpactDual Glazed w/Blinds*Grid Opt.Sash WgtTest Size
1251
Casement Outswing Left
3.7500.1250
AW 90
135<0.112.0000 0.486
0.283
43-46
YesNo Yes
A-I-T
120
36 X 60
1252
Casement Outswing Left-Casement Outswing Right
3.7500.1250
AW 90
135<0.112.0000 0.473
0.291
43-46
No Yes-72 X 60No
A-I-T
120
72 X 60
1253
Casement Outswing Left-Fixed
3.7500.1250
AW 90
135<0.112.0000 0.422
0.321
43-46
No No Yes
A-I-T
120
99 X 60
1254
Fixed-Casement Outswing Right
3.7500.1250
AW 90
135<0.112.0000 0.422
0.321
43-46
No No Yes
A-I-T
120
99 X 60
1255
Casement Outswing Right
3.7500.1250
AW 90
135<0.112.0000 0.486
0.283
43-46
YesNo Yes
A-I-T
120
36 X 60
1261
Casement Inswing Left
3.7500.1250
AW 90
135<0.112.0000 0.479
0.289
43-46
No No Yes
A-I-T
120
36 X 60
1265
Casement Inswing Right
3.7500.1250
AW 90
135<0.112.0000 0.479
0.289
43-46
No No Yes
A-I-T
120
36 X 60
1851
Casement Outswing Left
2.0000.1250
AW 100
150<0.112.00000.00000.430
0.300
36-41
YesYes-40 X 66Yes
A-I-T
120
36 X 60
1852
Casement Outswing Left- Casement Outswing Right
2.0000.1250
AW 75
112.5<0.112.00000.00000.419
0.306
36-41
No No Yes
A-I-T
120
72 X 60
1853
Casement Outswing Left- Fixed
2.0000.1250
AW 75
112.5<0.112.00000.00000.364
0.333
36-41
No No Yes
A-I-T
120
99 X 60
1854
Fixed- Casement Outswing Right
2.0000.1250
AW 75
112.5<0.112.00000.00000.364
0.333
36-41
No No Yes
A-I-T
120
99 X 60
1855
Casement Outswing Right
2.0000.1250
AW 100
150<0.112.00000.00000.430
0.300
36-41
YesYes-40 X 66Yes
A-I-T
120
36 X 60
1861
Casement Inswing Left
2.0000.1250
AW 100
150<0.112.00000.00000.424
0.300
36-41
No No Yes
A-I-T
120
36 X 60
1862
Casement Inswing Left- Casement Inswing Right
2.0000.1250
AW 100
150<0.112.00000.00000.415
0.304
36-41
No No Yes
A-I-T
120
72 X 60
1863
Casement Inswing Left- Fixed
2.0000.1250
AW 75
112.5<0.112.00000.00000.362
0.333
36-41
No No Yes
A-I-T
120
99 X 60
1865
Casement Inswing Right
2.0000.1250
AW 100
150<0.112.00000.00000.424
0.300
36-41
No No Yes
A-I-T
120
36 X 60
1951
Casement Outswing Left
4.5000.1250
AW 100
150<0.112.00000.00000.480
0.297
36-41
YesYes-40 X 66Yes
A-I-T
120
36 X 60
1955
Casement Outswing Right
4.5000.1250
AW 100
150<0.112.00000.00000.480
0.297
36-41
YesYes-40 X 66Yes
A-I-T
120
36 X 60
1961
Casement Inswing Left
4.5000.1250
AW 100
150<0.112.00000.00000.480
0.291
36-41
No No Yes
A-I-T
120
36 X 60
1965
Casement Inswing Right
4.5000.1250
AW 100
150<0.112.00000.00000.480
0.291
36-41
No No Yes
A-I-T
120
36 X 60
12
*Grid Options: A=Applied, I=Internal, T=True Muntin
**Avl = Available